![]() ![]() To obtain the exact length of the text, use the WM_GETTEXT, LB_GETTEXT, or CB_GETLBTEXT messages, or the GetWindowText function. For more information on ANSI and ANSI functions, see Conventions for Function Prototypes. It can also occur when an application uses the ANSI version of GetWindowTextLength with a window whose window procedure is Unicode, or the Unicode version of GetWindowTextLength with a window whose window procedure is ANSI. This behavior can occur when an application uses both ANSI functions and common dialogs, which use Unicode. The return value, however, will always be at least as large as the actual length of the text you can thus always use it to guide buffer allocation. bank sites(you can include GetWIndowText()1 function of windows API). This occurs with certain mixtures of ANSI and Unicode, and is due to the system allowing for the possible existence of double-byte character set (DBCS) characters within the text. Under certain conditions, the GetWindowTextLength function may return a value that is larger than the actual length of the text. If the target window is owned by the current process, GetWindowTextLength causes a WM_GETTEXTLENGTH message to be sent to the specified window or control. To determine success or failure, clear the most recent error information by calling SetLastError with 0, then call GetLastError. As the problem is generated due to incorrect behavior of a Citrix library, this needs to be reported to Citrix.This function does not clear the most recent error information.And as a fallback add the authentication in a retry scope if the CitrixApp it still fails. This should provide enough time for wfica32.exe to initialize correctly. Add a delay (10-15 seconds) before the “Wait for CitrixApp to load“ activity.However this cannot happen due to the crash. ![]() Normally this would execute as long as the Element Exist query times out. This unhandled exception then causes the whole wfica32.exe to crash and the Citrix App fails to launch. Most likely, there is an un-initialized variable somewhere in the vdtwin.dll code. One of those windows crashes with with "0xC0000094: Integer division by zero".On Citrix App launch, several windows are created from the wfica32.exe process.When running the workflow in order to obtain the Window Name used in the selecto, it is being executed the GetWindowText Win API call. Why is Citrix ICA Client Receiver/Citrix Workspace App crashing during execution? ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |